Product Description
The Goldman Halothane Vaporizer Unit with Threaded Bottle is a precision-engineered anesthesia equipment accessory designed for compatibility with conventional anesthesia delivery systems. Commonly referenced in clinical training materials such as Goldman vaporizer PPT resources, this vaporizer follows traditional vaporization principles used in operating theatre environments.
This unit features a threaded halothane vaporizer bottle mechanism, enabling secure attachment and controlled liquid agent handling. The compact construction allows easy integration with compatible breathing circuits and anesthesia assemblies.
The vaporizer’s identifiable halothane vaporizer color coding assists in visual recognition during setup. While historically compared with systems such as the copper kettle vaporizer, TEC 2 vaporizer, and modern isoflurane vaporizer units, this device remains relevant for educational, backup, or reference use.
Designed strictly as medical equipment, this product does not make therapeutic, diagnostic, or treatment outcome claims and should be used only by trained professionals in appropriate clinical or educational environments.
Technical Features
Goldman-style halothane vaporizer design
Threaded bottle mounting for secure agent placement
Compatible with standard anesthesia assemblies
Distinct halothane vaporizer color coding
Durable metal construction for long-term use
Suitable for training, reference, or clinical configurations
Usage Instructions
Install the vaporizer into a compatible anesthesia circuit
Secure the threaded halothane vaporizer bottle firmly
Verify fittings and connections before system operation
Operate according to institutional equipment handling guidelines
Clean external surfaces after use as per equipment protocol
Safety Disclaimer
This product is intended for use by trained professionals only. It is a medical equipment component and does not diagnose, treat, cure, or prevent any disease or condition. Usage must comply with institutional policies and regulatory standards. Always follow manufacturer and facility safety guidelines.
FAQ's
For certain models of the Goldman vapour unit, the design limits maximum halothane vapour output to about 3% by volume, regardless of the total fresh gas flow.
Note: Always verify the calibration and model‑specific data sheet for your unit.
While the principle applies to both, you must confirm the regulatory status and manufacturer’s indication for your region (veterinary vs human anaesthesia). Some older vaporizers were developed for dental/medical anesthesia. For example, the original Victor Goldman model was designed for dental use.
Verify the bottle is filled correctly and the threaded connection is tight.
Check that the control valve/ratchet is functioning and the dial is moving freely.
Ensure fresh gas flow is within recommended range. Extreme flows outside spec may affect performance.
Check ambient temperature and ensure unit is operated within manufacturer’s temperature compensation range.
Remove and service the unit if calibration drift is suspected — consult manufacturer’s servicing manual.
Easy returns
Free 7-day returns with quick refunds or easy exchanges and no stress.Free shipping
Enjoy fast, free shipping on all orders, no minimum, no hidden fees.Secure payment
Your information is protected with encrypted checkout and trusted payment methods.Quality assured
Every product is carefully tested to meet high standards of durability and performance.Alternative Products
These other products might interest you